Hambro Structural SystemsFIRE RATINGS
Hambro brings you one of the finest fire rated
structural floor systems in the
world.
There are many accepted methods to achieve
satisfactory fire protection of the Hambro floor system. Extensive
fire testing has been performed by Underwriters Laboratories (UL)
resulting in many milestones and again proving the superior
performance of the Hambro system. The full scale fire tests are
performed while the system is loaded to its full design capacity and
the results are overwhelming.
Gypsum drywall ceiling membranes installed directly
under Hambro joists are generally used in residential construction.
They are economical, aesthetically pleasing and can safely
accommodate integrated sub-systems, recessed light fixtures and
ventilating units without impairing their fire rating capabilities.
UL Design No. G-524 has been the most popular Hambro rating for
residential applications due to its enormous flexibility. For each
100 square feet of ceiling area, it allows unprotected plenum
ceiling penetrations up to 256 square inches for 1 hour, 196 square
inches for 1.5 hours and 100 square inches for 2 hours. Always
consult the latest listing published before
detailing.
Accessible ceiling panels commonly referred to as
"lay-in ceiling tiles
are generally used in office, commercial and institutional
construction. These removable panels allow access to the ceiling
plenum for alterations to mechanical or electrical
equipment.
Insulating the Hambro joist by sprayed on
fireproofing is another accepted method of fire
protection.
The following UL Designs all incorporate Hambro
joists. Always check your UL Directory for the latest updating of
these listings and applicable building codes before detailing
ceiling construction.
Gypsum Board
Membrane:
G-524, G-525,
Suspended or Lay-in
Ceiling:
G-003, G-213, G-222, G-227, G-228, G-229, G-236,
G-243
Sprayed-on
Fireproofing:
G-702, G-802,
G-803
The following are UL Ratings when designing with the
Hambro floor system.
|
Design No.
G003 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G201 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G203 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G211 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G213 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G222 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G227 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G228 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G229 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G236 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G243 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G268 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G301 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Most Used Design No. G524 |
Fire Resistance Ratings - ANSI/UL 263 |
|
|
Design No.
G525 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G702 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G706 |
Fire Resistance Ratings - ANSI/UL
263 |
|
|
Design No.
G802 |
Fire Resistance Ratings - ANSI/UL
263 |