UL FIRE RATINGS

FIRE RATINGS

 

Hambro brings you one of the finest fire rated structural floor systems in the world.

 

There are many accepted methods to achieve satisfactory fire protection of the Hambro floor system. Extensive fire testing has been performed by Underwriters Laboratories (UL) resulting in many milestones and again proving the superior performance of the Hambro system. The full scale fire tests are performed while the system is loaded to its full design capacity and the results are overwhelming.

 

Gypsum drywall ceiling membranes installed directly under Hambro joists are generally used in residential construction. They are economical, aesthetically pleasing and can safely accommodate integrated sub-systems, recessed light fixtures and ventilating units without impairing their fire rating capabilities. UL Design No. G-524 has been the most popular Hambro rating for residential applications due to its enormous flexibility. For each 100 square feet of ceiling area, it allows unprotected plenum ceiling penetrations up to 256 square inches for 1 hour, 196 square inches for 1.5 hours and 100 square inches for 2 hours. Always consult the latest listing published before detailing.

 

Accessible ceiling panels commonly referred to as "lay-in  ceiling tiles are generally used in office, commercial and institutional construction. These removable panels allow access to the ceiling plenum for alterations to mechanical or electrical equipment.

Insulating the Hambro joist by sprayed on fireproofing is another accepted method of fire protection.

The following UL Designs all incorporate Hambro joists. Always check your UL Directory for the latest updating of these listings and applicable building codes before detailing ceiling construction.

 

Gypsum Board Membrane:

G-524, G-525,

 

Suspended or Lay-in Ceiling:

G-003, G-213, G-222, G-227, G-228, G-229, G-236, G-243

 

Sprayed-on Fireproofing:

G-702, G-802, G-803

The following are UL Ratings when designing with the Hambro floor system.

Design No. G003

Fire Resistance Ratings - ANSI/UL 263

BXUV.G003

Design No. G201

Fire Resistance Ratings - ANSI/UL 263

BXUV.G201

Design No. G203

Fire Resistance Ratings - ANSI/UL 263

BXUV.G203

Design No. G211

Fire Resistance Ratings - ANSI/UL 263

BXUV.G211

Design No. G213

Fire Resistance Ratings - ANSI/UL 263

BXUV.G213

Design No. G222

Fire Resistance Ratings - ANSI/UL 263

BXUV.G222

Design No. G227

Fire Resistance Ratings - ANSI/UL 263

BXUV.G227

Design No. G228

Fire Resistance Ratings - ANSI/UL 263

BXUV.G228

Design No. G229

Fire Resistance Ratings - ANSI/UL 263

BXUV.G229

Design No. G236

Fire Resistance Ratings - ANSI/UL 263

BXUV.G236

Design No. G243

Fire Resistance Ratings - ANSI/UL 263

BXUV.G243

Design No. G268

Fire Resistance Ratings - ANSI/UL 263

BXUV.G268

Design No. G301

Fire Resistance Ratings - ANSI/UL 263

BXUV.G301

Most Used

Design No. G524

Fire Resistance Ratings - ANSI/UL 263

BXUV.G524

Design No. G525

Fire Resistance Ratings - ANSI/UL 263

BXUV.G525

Design No. G702

Fire Resistance Ratings - ANSI/UL 263

BXUV.G702

Design No. G706

Fire Resistance Ratings - ANSI/UL 263

BXUV.G706

Design No. G802

Fire Resistance Ratings - ANSI/UL 263

BXUV.G802